Escalib Mills_GB

M I N I E S C A L I B M I L L S : S I T E S P I R A L S T A I R T O W E R W I T H S I D E E X I T . 38 MINI Escalib Mills: specifications and load capacity... If “d” is greater than 20 cm, wind bracing may be required to reinforce the anchor system. Configuration 2 requires special calculations. For a given direction, forces in both directions must be taken into account. > Arrangement of the anchors: Configuration 1: d ≤ 20 cm Configuration 2: 20 cm < d < 2.00 m Anchor Anchor Anchor V T V T Anchor d d WARNING: When the Escalib is no longer self-supporting, a stabilizing device is required. T o make it easier to dimension the anchorage points and ground bearing for the Escalib Mills,the ground load calculations and the forces at the anchorage points are given for the various configurations. Assumptions: I -Wind action as in NF EN 1991-1-4: - f = 0.30 and Cf = 2.35 -Vp: Wind speed (km/h). - q p Peak wind dynamic pressure (daN/m²). 2 -Working load Q: - Standards NF P93-521 and NF EN 12811. - Up to 8 persons per Escalib Mills module. - Up to a maximum of 20 persons for the complete Escalib Mills modules. - Stair tower not to be used in winds of over 65 km/h. 3 -WeightW of the Escalib Mills tower. > Dimensions of the MINI Escalib Mills: > Dimensions with 7-step ballasted Mini base. No.of modules Side against wall 8 max. floor slab at 20.1 m 7 max. floor slab at 17.6 m 6 max. floor slab at 15.1 m 5 max. floor slab at 12.6 m 4 max. floor slab at 10 m 3 max. floor slab at 7.5 m 2 max. floor slab at 5.0 m 1 max. floor slab at 2.5 m Configuration of a MINI Escalib Mills: Configuration of a MINI Escalib Mills with 7-step ballasted base: Description Code Unit Compositions weight Mini module 014120-0 307 1 2 3 4 5 6 7 Mini barrier gate 013119-3 15 1 1 1 1 1 1 1 7-step ballasted Mini base 014123-4 875 1 1 1 1 1 1 1 Total weight 1192 1499 1806 2113 2420 2727 3034 Max. height serviced 3.7 6.3 8.8 11.3 13.8 16.3 18.8 Weights are in kg. Heights are in meters Description Code Unit Compositions weight Mini module 014120-0 307 1 2 3 4 5 6 7 8 Mini barrier gate 014122-6 10.5 1 1 1 1 1 1 1 1 Mini base 014121-8 147 1 1 1 1 1 1 1 1 Total weight 465 772 1079 1386 1693 2000 2307 2614 Max. height serviced 2.5 5.0 7.5 10.0 12.6 15.1 17.6 20.1 Weights are in kg. Heights are in meters No.of modules Height of the floor slab being serviced (m) Side against wall 7 max. floor slab at 18.8 m 6 max. floor slab at 16.3 m 5 max. floor slab at 13.8 m 4 max. floor slab at 11.3m 3 max. floor slab at 8.8 m 2 max. floor slab at 6.3 m 1 max. floor slab at 3.7 m 7-step base The anchoring can be composed of an anchoring cap and of an Escalib Mills coupler (see chapter Additional components). NT 010 - ESCALIB MILLS TECHNICAL INFORMATION Height of the floor slab being serviced (m) B 19.7 to 20.1 C 19.0 to 19.7 D 18.4 to 19.0 A 17.8 to 18.4 B 17.2 to17.617.6 to17.8 C 16.5 to 17.2 D 15.9 to 16.5 A 15.3 to 15.9 B 14.6 to15.115.1 to15.3 C 14.0 to14.6 D 13.4 to14.0 A 12.8 to13.4 B 12.1 to12.612.6 to12.8 C 11.5 to 12.1 D 10.9 to 11.5 A 10.2 to 10.9 B 9.6 to 10.010.0 to10.2 C 9.0 to9.6 D 8.4 to 9.0 A 7.7 to 8.4 B 7.1 to 7.5 7.5 to7.7 C 6.5 to 7.1 D 5.8 to 6.5 A 5.2 to 5.8 B 4.6 to5.0 5.0 to5.2 C 3.9 to 4.6 D 3.3 to 3.9 A 2.7 to 3.3 B 2.0 to 2.5 2.5 to 2.7 C 1.4 to 2.0 D 0.8 to 1.4 B 18.4 to 18.8 C 17.8 to 18.4 D 17.2 to 17.8 A 16.5 to 17.2 B 15.9 to 16.316.3 to 16.5 C 15.3 to15.9 D 14.6 to15.3 A 14.0 to14.6 B 13.4 to 13.813.8 to 14 C 12. 8 to 13.4 D 12.1 to 12.8 A 11.5 to 12.1 B 10.9 to 11.311.3 to 11.5 C 10.2 to 10.9 D 9.6 to 10.2 A 9.0 to 9.6 B 8.4 to 8.8 8.8 to 9.0 C 7.7 to 8.4 D 7.1 to 7.7 A 6.5 to 7.1 B 5.8 to 6.3 6.3 to 6.5 C 5.2 to 5.8 D 4.6 to 5.2 A 3.9 to 4.6 B 3.3 to 3.7 3.7 to 3.9 C 2.7 to 3.3 D 2.0 to 2.7 A 1.4 to 2.0 B 0.8 to 1.2 1.2 to 1.4

RkJQdWJsaXNoZXIy OTQ2MzM=