Escalib Mills_GB

E S C A L I B M I L L S : S I T E S P I R A L S T A I R T O W E R W I T H S I D E E X I T . 23 > Crane installation of front access gangway: The installation phase requires a safety harness (individual fall arrest system) to be worn. > 1 - Install the left and right-hand gangway brackets. Depending on the configuration, fit the gangway board bearer at the top or at the bottom on the brackets. > 2 - Lanyard attached to the module, swing guardrails out of the way to allow gangway installation. > 3 - Remove the floor slab edge guardrails. Gangway dropped in place. Remove the screw jack couplers temporarily for height adjustment. >The board bearer and the gangway bracket can be replaced with the “MDS Gangway bracket” but the installation also requires the wearing of harnesses. It must be pre-assembled with the scaffolding gangway. WARNING: Anchor the Escalib Mills at gangway level. REQUIREMENTS: > Dismantle in the reverse order of assembly. Right Left > GANGWAY SUPPORT Description Code Weight Left support 013271-2 13.0 Right support 013270-4 9.0 > GANGWAY BEARER WITH BOLTS Description Code Weight Gangway board bearer with bolts 013415-5 16.2 1.00 2 M10-100-8.8 bolts 1.50 Jack couplers. > Components: See the Mills Acram technical information for other scaffolding items. WARNING: Assembly with harness (PPE). Gangway bearer with bolts Support ESCALIB MILLS NT 010 - ESCALIB MILLS TECHNICAL INFORMATION

RkJQdWJsaXNoZXIy OTQ2MzM=